<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>University of Mohaghegh Ardabili</PublisherName>
				<JournalTitle>Journal of Operation and Automation in Power Engineering</JournalTitle>
				<Issn>2322-4576</Issn>
				<Volume>9</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2021</Year>
					<Month>08</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>A Practical Approach for Coordinated Transmission Switching and OLTCs’ ‎Tap Adjustment: DIgSILENT-Based Improved PSO Algorithm</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>103</FirstPage>
			<LastPage>115</LastPage>
			<ELocationID EIdType="pii">1036</ELocationID>
			
<ELocationID EIdType="doi">10.22098/joape.2021.7378.1533</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>A.</FirstName>
					<LastName>Bagheri</LastName>

						<AffiliationInfo>
						<Affiliation>Department of Electrical Engineering, Faculty of Engineering, University of Zanjan, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Planning and Research Deputy, Zanjan Regional Electric Company, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

</Author>
<Author>
					<FirstName>A.</FirstName>
					<LastName>Rabiee</LastName>

						<AffiliationInfo>
						<Affiliation>Department of Electrical Engineering, Faculty of Engineering, University of Zanjan, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Planning and Research Deputy, Zanjan Regional Electric Company, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

</Author>
<Author>
					<FirstName>S.</FirstName>
					<LastName>Galavani</LastName>

						<AffiliationInfo>
						<Affiliation>Planning and Research Deputy, Zanjan Regional Electric Company, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Faculty of Electrical and Computer Engineering, Urmia University, Urmia, Iran</Affiliation>
						</AffiliationInfo>

</Author>
<Author>
					<FirstName>H.</FirstName>
					<LastName>Yassami</LastName>

						<AffiliationInfo>
						<Affiliation>Planning and Research Deputy, Zanjan Regional Electric Company, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Saba Power Plant, Operation and Maintenance Company, Tehran, Iran</Affiliation>
						</AffiliationInfo>

</Author>
<Author>
					<FirstName>A.</FirstName>
					<LastName>Moeini</LastName>

						<AffiliationInfo>
						<Affiliation>Department of Electrical Engineering, Faculty of Engineering, University of Zanjan, Zanjan, Iran</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Hydro Quebec Research Institute, Quebec, Canada</Affiliation>
						</AffiliationInfo>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2020</Year>
					<Month>06</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		<Abstract>Transmission lines switching and tap adjustment of power transformers are short-term alternatives to enhance the flexibility of power system operation. By a proper implementation of these alternatives, the operational problems such as lines congestion, bus voltage violations and excessive power losses can be alleviated. Traditionally, these two alternatives are applied separately due to the complexity of their simultaneous implementation as well as their coordination. In this paper, a DIgSILENT-based improved particle swarm optimization (IPSO) algorithm is proposed to implement the transmission switching and coordinated voltage control of power transformers, concurrently. The IPSO is implemented in DPL environment of Powerfactory-DIgSILENT, as a powerful software package commonly used by the electrical utilities. The proposed approach is applied to IEEE-14 bus system and the real transmission network of Zanjan Regional Electric Company (ZREC) located in Iran, in different scenarios considering all the existing practical constraints. The obtained results verify the effectiveness of the presented approach.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Transmission switching</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">OLTC’s tap adjustment</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Improved PSO</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">DIgSILENT</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://joape.uma.ac.ir/article_1036_fbbfd843633bcd1e3eebff1c998a9731.pdf</ArchiveCopySource>
</Article>